MASSFLOW - precise gas flow measurement and controller

The LAMBDA MASSFLOW is a new mass flow controller system especially designed for use with LAMBDA laboratory bioreactors and fermentors. For example, it allows control of the pH of a cell culture by the controlled addition of gaseous CO2, the control of dissolved oxygen by regulation of the airflow or any other gas with a suitable controller. However, it can also be used independently, since all its functions can be controlled from the front panel of the MASSFLOW.
The flow rate is measured by high quality laminar mass flow sensor tubes and is displayed on a digital display. The mass flow cell has a very low-pressure drop (less than 1 cm of H2O) and a linearity error of less than ±3% reading (which is much better than the precision expressed as a percentage of full scale used by some manufacturers). The repeatability is better than ±0.5% reading. The flow rate is regulated by a specially developed proportional needle valve controlled by a microprocessor.
MASSFLOW can be operated manually with the buttons on the front panel or using the remote control. The analogical remote control includes ON/OFF and 0 to 10 V full-scale control of the flow rate. Digital control can be achieved by the optional RS-485 interface.
Features of LAMBDA MASSFLOW Gas controller and meter
- Stand-alone instrument; stand-alone MASSFLOW units controlled by PNet software or used together with MINIFOR fermentor-bioreactor
- High-quality laminar mass flow sensor
- Mass flow cell shows minimal pressure drop
- Linearity error less than ± 3 % reading
- Repeatability better than ± 0.5% reading
- Programmable gas flow rate (controller only) and volume totalizer (Pump-flow INTEGRATOR)
PRECISE REGULATION |
AUTOMATIC GAS MIX
|
O2 ENRICHMENT |
MASSFLOW with proprietary proportional needle valve provides precise measurement independent of pressure, temperature or humidity |
MINI-4-GAS, gas-mixing module allows a flexible and controlled supply of different gases with PNet software for mammalian cell cultures |
MASSFLOW gas flow controller for the high cell density bacterial and yeast cultures under optimized fed-batch fermentation processes |
Programming:
Up to 50 pairs of flow rates and times can be programmed. This allows the flow to be switched on and off or the setting of any flow rate for a desired time interval.
Gas volume totaliser:
MASSFLOW generates impulsions after every 5 ml of gas flow. These impulsions can be totalled LAMBDA INTEGRATOR (cat.no: 4803), measured as a voltage, recorded on a recorder or on a PC (e.g. fermentation program FNet or SIAM). In this way exact volume information can be obtained.
Zero setting:
MASSFLOW is equipped with an automatic zero setting which further improves the precision of the flow rate reading. This function allows precise calibration when other gases are used.
MINI-4-GAS:
LAMBDA offers MINI-4-GAS, an automatically controlled gas mixing module for MINIFOR bioreactor and fermentor to maintain the optimal physiologic conditions of your mammalian and stem cell cultures using modern control strategies
Types of MASSFLOW controller and meter
MASSFLOW gas flow controller
|
MASSFLOW gas flow meter (only) |
|||
MASSFLOW 5000 |
MASSFLOW 500 |
MASSFLOW 5000-s |
MASSFLOW 500-s |
MASSFLOW 500-hs |
Art. No.: 8071 |
Art. No.: 8072 |
Art. No.: 8071-s |
Art. No.: 8072-s |
Art. No.: 8072-hs |
Flow range: |
Flow range: |
Flow range: |
Flow range: |
Flow range: 100 - 500 ml/min in |
Gases: Air / N2 / O2 or CO2 / Ar |
Gases: Air / N2 / O2 or CO2 / Ar / He / H2 |
Gases: Air / O2 / N2 or others |
Gases: Air / O2 / N2 or others |
Gases: Air / O2 / N2 or others |
Programmable: |
Programmable: |
Meter only |
Meter only |
Meter only |
Remote control: |
Remote control: |
RS-485 or RS-232 connection |
RS-485 or RS-232 connection |
RS-485 or RS-232 connection |
Technical specifications
Type |
LAMBDA MASSFLOW – microprocessor-controlled gas flow controller (controller only) and gas flow meter |
Accuracy |
± 3% reading or 1 digit |
Repeatability |
± 0.5 % reading or 1 digit |
Flow range |
|
MASSFLOW 5000 |
0 - 5.00 l/min in 0.01 l/min steps (controller or meter) |
MASSFLOW 500 |
0 - 500 ml/min in 1 ml/min steps (controller or meter) |
MASSFLOW 5000-s |
0 - 5.00 l/min in 0.01 l/min steps (meter only) |
MASSFLOW 500-s |
0 - 500 ml/min in 1 ml/min steps (meter only) |
MASSFLOW 500-hs |
Auto-range: 0 - 99.9 ml/min in 0.1 ml/min steps and 100 - 500 ml/min in 1 ml/min steps (meter only) |
Calibration |
N2/Air (pre-calibrated sensors for other gases available on request) |
Non-volatile memory |
storage of all settings |
Maximum pressure |
0.2 MPa (2 bar) |
Power supply |
90–240 V/50–60 Hz AC plug-in power supply with DC 12V/24W output; possible field operation on 12 V accumulator |
Interface |
RS-485 or RS-232 (optional) |
Remote control |
0-10 V; (option 0-20 or 4-20 mA) (controller only) |
Dimensions |
10.5 (W) × 8 (H) × 17 (D) cm |
Weight |
800 g |
Safety |
CE, meets IEC 1010/1 norm for laboratory instrument |
Operation temperature |
0 – 40 ⁰C |
Operation humidity |
0-90% RH, not condensing |